1056 Dual Input Analyzer

1056 Dual Input Analyzer

PROGRESSION OF THE DUAL INPUT ANALYZER
The new model 1056 Analyzer from Rosemount offers all of the same great features found on the model 1055 with some improvements. The first improvement of notice is the large display for both process measurements and bright contrast LCD display. The model 1055 will still be offered for quite some time, and supported far past that, for people who have standardized on this transmitter and would like to continue to do so.

FEATURES AND APPLICATIONS
The Model 1056 dual-input analyzer offers single or dual sensor input with an unrestricted choice of dual measurements thus reducing the cost per loop and saving panel space. This multi-parameter instrument offers a wide range of measurement choices, including differential conductivity, dual oxygen and many other combinations supporting most industrial, commercial, and municipal applications. The modular design of the instrument allows signal input boards to be field replaced making configuration changes easy. Conveniently, live process values are always displayed during programming and calibration routines. Standard features include isolated inputs, 6 embedded local languages, two 4-20mA current outputs, removable connectors for power and current outputs, four solid plugs for closure of openings, and panel mount hardware.

  • QUICK START PROGRAMMING: Exclusive Quick Start screens appear the first time the Model 1056 is powered. The instrument auto-recognizes each measurement board and the display prompts the user to configure each sensor in a few quick steps for immediate deployment.
  • MENUS: Menu screens for calibrating and programming are simple and intuitive. Plain language prompts and help screens guide the user through these procedures.
  • DUAL SENSOR INPUT AND OUTPUT: The Model 1056 accepts single or dual sensor input. Standard 0/4-20 mA current outputs can be programmed to correspond to any measurement or temperature.
  • ENCLOSURE: The instrument fits standard ½ DIN panel cutouts. The versatile enclosure design supports panel-mount, pipe-mount, and surface/wall-mount installations.
  • ISOLATED INPUTS: Inputs are isolated from other signal sources and earth ground. This ensures clean signal inputs for single and dual input configurations. For dual input configurations, isolation allows any combination of measurements and signal inputs without cross-talk or signal interference.
  • TEMPERATURE: Most measurements require temperature compensation. The Model 1056 will automatically recognize Pt100, Pt1000 or 22k NTC RTDs built into the sensor.

For more information or a complete Data Sheet, please contact your local sales representative.